ASET presents this document to provide national criteria for evaluating competencies for performing intraoperative neurophysiologic monitoring (IONM). Intraoperative neurophysiologic monitoring is an advanced level of practice in the neurodiagnostic field. Training and education should reflect this advanced level and achievement of recognized professional credentials should be accomplished.
ASET presents this document to provide the national criteria for evaluating competencies for technologists performing a Magnetoencephalogram (MEG).
ASET presents this document to provide national criteria for evaluating competencies for performing studies associated with continuous EEG monitoring in neonatal Intensive Care Units with a postmenstrual age of less than 48 weeks.
ASET presents this document to provide national criteria for evaluating the competencies needed by technologists to perform Nerve Conduction Studies (NCS).
ASET presents this document to provide national criteria for evaluating the competencies needed by technologists to perform Polysomnography/Sleep Technology.
With the increasing popularity of generative AI tools it has become necessary to outline the proper use of such tools when contributing content to ASET’s NeuroCurrents member magazine.
The Neurodiagnostic Assistant continuously monitors patients undergoing cEEG recording for safety, either in room or via remote video monitoring and alerts nursing and/or technologist staff when clinical seizures or other paroxysmal events occur. Not qualified to analyze EEG data.
Navigating the world of neurodiagnostic credentials can be complex. This comprehensive resource hub simplifies the process, offering a central location for all your credentialing needs.
This document, a position statement from ASET, outlines the recommended qualifications for neurodiagnostic personnel to ensure optimal and quality neurological patient care. ASET encourages the widespread adoption of these personnel qualifications, as outlined in the position statement, to guarantee safe and effective patient care within communities.
When sedation is determined to be necessary to obtain an adequate neurodiagnostic study that meets technical recording standards, anesthesiologists, nursing, or anesthesia personnel with appropriate qualifications must be present before, during, and after the procedure to evaluate patient status and assure patient safety.
Designed to quickly orient you to what peer review is and answer the most frequently asked questions.
Designed for administrators, faculty and others instrumental in the development of allied health programs, this publication provides the basics in establishing a Neurodiagnostic Technology (NDT) program, including a chapter specific to Polysomnography (PSG).
The ASET Program Directors Council brings together directors of neurodiagnostic technology programs to discuss best practices and current issues in technologist education. The group shares ideas, resources, and best practices to improve neurodiagnostic education. The council meets monthly but also offers educational webinars for the programs, their staff, and clinical sites throughout the year.
Neurodiagnostic procedures and interpretation are part of the patient’s legal heath record. Data related to neurodiagnostic procedures should be stored on reliable, secured electronic media such as CD, DVD, or dedicated server.
Use this script to request that Neurodiagnostic Week be recognized by your city or state.
The purpose of this document is to define the Scope of Practice for neurodiagnostic technologists and to specify their role as members of the healthcare team following evidence-based outcomes and practice. The Scope of Practice document is based on current and evolving standards and practices, guidelines, regulatory requirements, and technologies.
This Position Statement argues that Neurodiagnostic professionals (i.e., technologists, specialists, surgical neurophysiologists, etc.) who perform IONM procedures should monitor only one surgical procedure at a time.
The ASET Standards & Practice, Skin Safety Task Force was charged with developing best practices to protect the skin integrity of patients undergoing EEG procedures.
The Skin Safety Task Force began with developing addenda for neonates and patients with dermatologic skin conditions; this addendum addresses neonatal patients undergoing continuous EEG.
The Statement of Professional Ethics are standards to guide Neurodiagnostic Technologists in their professional activities. These standards are not laws but codes that are fundamental to responsible delivery of patient care.
Learn why it's in the public interest to support neurodiagnostic licensure
Neurodiagnostic technologists are often asked to be on-call in order to provide emergency diagnostic or monitoring services after regular working hours. On-call policies and procedures should not conflict with the prescribed Scope of Practice for Neurodiagnostic Technologists.
Since NCPAP's inception in the early 1980s, Polysomnographic Technologists have been using NCPAP and performing titrations of the NCPAP device in conjunction with the sleep study.